| Additional Information | American Bureau Shipping Certificate No. 00-3K50288-X, Lloyd's Register Certificate No. 01/10075, Germanischer Lloyd Certificate No. 57798-91 HH, DET Norske Veritas Certificate No. P-9100 | 
                            
                                | Tube O.D. (in) | 1/2 | 
                            
                                | Dimension L (mm) | 64.8 | 
                            
                                | Material | Bodies Glands and Nuts - 316 stainless steel, Automatic Tube Weld Fittings - 316L stainless steel, O - RING - 70 durometer fluorocarbon ( Viton ) is standard on ZCO bodies . 90 durometer fluorocarbon is used with SAE / MS threads. | 
                            
                                | Dimension d (in) | 0.400 | 
                            
                                | Dimension L (in) | 2.550 | 
                            
                                | Dimension L₁ (in) | 1.650 | 
                            
                                | Dimension L₂ (in) | 0.900 | 
                            
                                | Dimension L₁ (mm) | 41.9 | 
                            
                                | Dimension d (mm) | 10.16 | 
                            
                                | Working Pressure (psig) | 6700 | 
                            
                                | Working Pressure (bar) | 460 | 
                            
                                | Dimension L₂ (mm) | 22.86 | 
                            
                                | Panel Hole Size (in) | 49/64 | 
                            
                                | Hex Flat H (in) | 15/16 | 
                            
                                | Size (in) | 1/2 | 
                            
                                | Installation Instructions | Install ZCO body to existing port, tubing or equipment. Assemble ZCO body with ZCO female nut and gland and tighten nut 1/8 turn with a wrench after finger tight to make sure metal to metal contact. When ZCO body or gland needs soldering, welding or brazing procedures, the O-ring should be removed to prevent possible damage.
 | 
                            
                                | Hex Flat H₁ (in) | 15/16 | 
                            
                                | Hex Flat H₂ (in) | 7/8 | 
                            
                                | Max. Panel Thickness (in) | 0.500 |