Catalog

Q3BBH-12M Q Series Bulkhead Tube Body Connector Fittings

Model: Q3BBH-12M

Request Quote Quantity

Product Details

  • Gauge Calibration
  • Sampling System
  • Portable Test Equipment
  • Laboratory Equipment
  • Gas Distribution
  • Biopharmaceutical
  • Easy to use.
  • Minimum equipment shutdown.
  • No tools required to make or break a connection.
  • No probability of cross threading, galling, under or over-tightening.
  • Interchangeable with same type of Swagelok, Parker, Hoke and TOMCO components.
  • Single End Shut Off (SESO) - This Quick Connector style features body only shut off. Stem is open to atmosphere when disconnected.
  • Double End Shut Off (DESO) - This Quick Connector style features both body and stem shut off at disconnection with a minimal amount of spillage and air inclusion.
  • Use filters in front of quick connectors.
  • Protect uncoupled body and stem with body and stem protectors or dust caps.
  • Keep body and stem aligned when coupling and uncoupling.
  • Couple and uncouple the quick connectors at room temperature.
  • Couple and uncouple the quick connectors during system cleaning operations.
  • Support hanging hoses or other equipment to prevent side load.
  • Re-lubricate stem seal O-rings periodically.
Caution Single-end quick connectors MUST be depressurized prior to disconnection.
Series Q3
Width Across Flat (H) (mm) 24.00
Diameter (D) (in) 1.210
Working Pressure (psig) Up to 3000
Working Pressure (bar) Up to 206
Notes Long Life Cycle.
Dimensions shown with Hy-Lok nuts in finger-tight position, where applicable.
All dimensions are in millimeters unless otherwise specified. Dimensions are for reference only, subject to change.
End Connection Size (in) 1/4 ~ 1/2
Tube Outside Diameter (mm) 12.00
Length (L) (in) 3.560
Length (L) (mm) 90.40
Temperature Rating with FKM O-Ring (ºC) -23 ~ 204
Temperature Rating with FKM O-Ring (ºF) -10 ~ 400
O-Ring Material Options NBR: -10 to 250 ºF (-23 to 121 ºC), FFKM: -10 to 600 ºF (-23 to 315 ºC), Neoprene: -40 to 250 ºF (-40 to 121 ºC), Ethylene Propylene: -50 to 300 ºF (-46 to 149 ºC)
Spillage (cm³) 3.0
Air Inclusion (cm³) 3.0
Maximum Water Flow Coefficient (Cv) Rate at 70 ºF (20 ºC) (gpm) 10
Maximum Water Flow Coefficient (Cv) Rate at 70 ºF (20 ºC) (L/min) 37.8
Minimum Panel Hole Diameter (in) 49/64
Minimum Panel Hole Diameter (mm) 19.60
Maximum Panel Thickness (in) 0.260
Maximum Panel Thickness (mm) 6.60
Diameter (D) (mm) 30.70

HAVE A QUESTION?

If you have any questions about any of our products or services, don’t hesitate to give us a call. For any inquiries, fill out the form and one of our Hy-Lok representative will contact you soon.

Sign Up TO Join Our Newsletter